Customization: | Available |
---|---|
Certification: | CE, ISO |
Customized: | Customized |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SN | Description | Unit | Data |
1 | Rated capacity | t | 20t |
2 | Max. tapping per heat | t | 25t |
3 | Diameter of shell | mm | Φ4,000 |
4 | Electrode pitch circle diameter | mm | Φ800 |
5 | Electrode diameter | mm | Φ400 |
6 | Electrode travel stroke | mm | 2,800 |
7 | Electrode lifting speed(up/down) | m/min | 6/4 |
8 | Max. tilting angle (steel tapping / slagging) | 20° / 12° | |
9 | Max. roof swivel angle | 80° | |
10 | Roof lifting stroke | mm | 400 |
11 | Transformer capacity | kVA | 12,500 |
12 | Transformer primary voltage | kV | 20 |
13 | Transformer secondary voltage | V | 350-290-170 |
14 | Cooling water circulating flow rate | t/h | 300 |
15 | Furnace door size | mm | 800×640 |
SN | Item | Qty | Remark |
1 | Furnace body (Upper shell, lower shell) | 1 | |
2 | Tilting platform mechanism | 1 | |
3 | Water cooled roof | 1 | |
4 | Roof lifting & swivel mechanism | 1 | |
5 | Conductive arms | 1 | |
6 | Electrode lifting mechanism | 1 | |
7 | Cooling water distributor | 1 | |
8 | Electrode connection device | 1 | |
9 | Hydraulic power pack | 1 | Proportional valve and pump make: Parker |
10 | Short net & water cooled cables | 1 | |
11 | L.V. Control system (GGD panel) | 1 | |
12 | PLC control system & HMI | 1 | Siemens S7-300 |
13 | Furnace transformer & hydro-oil cooler | 1 | China make |
14 | H.V. switchboard (GBC type panel) | 1 | china VCB |